Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38619048

RESUMO

AIMS: A three-dimensional electroanatomic mapping system-guided transseptal puncture (3D-TSP), without fluoroscopy or echocardiography, has been only minimally reported. Indications for 3D-TSP remain unclear. Against this background, this study aims to establish a precise technique and create a workflow for validating and selecting eligible patients for fluoroless 3D-TSP. METHODS AND RESULTS: We developed a new methodology for 3D-TSP based on a unipolar electrogram derived from a transseptal needle tip (UEGM tip) in 102 patients (the derivation cohort) with intracardiac echocardiography (ICE) from March 2018 to February 2019. The apparent current of injury (COI) was recorded at the muscular limbus of the foramen ovalis (FO) on the UEGM tip (sinus rhythm: 2.57 ± 0.95 mV, atrial fibrillation: 1.92 ± 0.77 mV), which then disappeared or significantly reduced at the central FO. Changes in the COI, serving as a major criterion to establish a 3D-TSP workflow, proved to be the most valuable indicator for identifying the FO in 99% (101/102) of patients compared with three previous techniques (three minor criteria) of reduction in atrial unipolar or bipolar potential and FO protrusion. A total of 99.9% (1042/1043) patients in the validation cohort underwent successful 3D-TSP through the workflow from March 2019 to July 2023. Intracardiac echocardiography guidance was required for 6.6% (69/1042) of patients. All four criteria were met in 740 patients, resulting in a 100% pure fluoroless 3D-TSP success rate. CONCLUSION: In most patients, fluoroless 3D-TSP was successfully achieved using changes in the COI on the UEGM tip. Patients who met all four criteria were considered suitable for 3D-TSP, while those who met none required ICE guidance.


Assuntos
Fibrilação Atrial , Técnicas Eletrofisiológicas Cardíacas , Imageamento Tridimensional , Punções , Humanos , Masculino , Feminino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Técnicas Eletrofisiológicas Cardíacas/métodos , Idoso , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Agulhas , Septos Cardíacos/cirurgia , Septos Cardíacos/diagnóstico por imagem , Fluxo de Trabalho , Ecocardiografia
2.
J Arrhythm ; 40(2): 374-376, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38586835

RESUMO

A patient with shocks from his ICD related to AF underwent redo ablation. The only identifiable target was the superior vena cava. This was isolated using ultra-low cryotherapy, eliminating episodes of AF.

3.
Artigo em Inglês | MEDLINE | ID: mdl-37977548

RESUMO

OBJECTIVE: To investigate the utility of simultaneous multi-catheter cryotherapy for the treatment of APs that were previously resistant to standard radiofrequency (RF) catheter ablation. BACKGROUND: Catheter ablation is established in the treatment of accessory pathways (AP), with high rates of permanent procedural success with a single attempt. However, there are still instances of acute procedural failure and AP recurrences with standard RF and cryotherapy methods. METHODS: Seven consecutive cases of pre-excitation syndromes with prior failed RF catheter ablation had the novel treatment. Cryotherapy was delivered using two 8 mm tip focal cryoablation catheters (Freezor® Max, Medtronic, Minneapolis, Minnesota, USA). RESULTS: Accessory pathway localisation was septal in 5 cases, left posterolateral in 1, right lateral in 1. In all cases, ablation of the AP was acutely successful with no procedural complications. Median procedure and fluoroscopy durations were 199 and 35 min, sequentially. Median Procedure duration fell significantly in the second half of series (174 min) compared to the first half (233 min, P = 0.05). One patient had evidence of a recurring AP conduction with pre-excitation at 5-week follow up. After a median follow up of 66.8+-6.5 months, 6 out of 7 patients remained asymptomatic and free of pre-excitation. CONCLUSION: Simultaneous multi-catheter cryotherapy is feasible, safe and can provide definitive cure of accessory pathways that were previously resistant to standard radiofrequency ablation. Further study is required in the assessment of this novel form of advanced cryotherapy to treat complex and resistant arrhythmias.

4.
Brain Behav Immun Health ; 34: 100699, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38058985

RESUMO

Treatment modalities for breast cancer, including cyclophosphamide chemotherapy, have been associated with the development of cognitive decline (CRCD), which is characterized by impairments in memory, concentration, attention, and executive functions. We and others have identified a link between inflammation and decreased cognitive performance in patients with breast cancer receiving chemotherapy. In order to better understand the inflammation-associated molecular changes within the brain related to tumor alone or in combination with chemotherapy, we orthotopically implanted mouse mammary tumors (E0771) into female C57BL/6 mice and administered clinically relevant doses of cyclophosphamide and doxorubicin intravenously at weekly intervals for four weeks. We measured serum cytokines and markers of neuroinflammation at 48 h and up to one month post-treatment and tested memory using a reward-based delayed spatial alternation paradigm. We found that breast tumors and chemotherapy altered systemic inflammation and neuroinflammation. We further found that the presence of tumor and chemotherapy led to a decline in memory over time at the longest delay, when memory was the most taxed, compared to shorter delay times. These findings in a clinically relevant mouse model shed light on possible biomarkers for CRCD and add to the growing evidence that anti-inflammatory strategies have the potential to mitigate cancer- or treatment-related side effects.

5.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37936325

RESUMO

AIMS: Transvenous lead extraction (TLE) is important in the management of cardiac implantable electronic devices but carries risk. It is most commonly completed from the superior access, often with 'bail-out' support via the femoral approach. Superior and inferior access may be used in tandem, which has been proposed as an advance in safety and efficacy. The aim of this study is to evaluate the safety and efficacy of the Tandem approach. METHOD: The 'Tandem' procedure entailed grasping of the targeted lead in the right atrium to provide countertraction as a rotational dissecting sheath was advanced over the lead from the subclavian access. Consecutive 'Tandem' procedures performed by a single operator between December 2020 and March 2023 in a single large-volume TLE centre were included and compared with the conventional superior approach (control) using 1:1 propensity score matching; patients were statistically matched for demographics. RESULTS: The Tandem in comparison with the conventional approach extracted leads of much greater dwell time (148.9 ± 79 vs. 108.6 ± 77 months, P < 0.01) in a shorter procedure duration (96 ± 36 vs. 127 ± 67 min, P < 0.01) but requiring more fluoroscopy (16.4 ± 10.9 vs. 10.8 ± 14.9 min, P < 0.01). The Tandem and control groups had similar clinical (100% vs. 94.7%, P = 0.07) and complete (94.8% vs. 92.8%, P = 0.42) success, with comparable minor (4% vs. 6.7%, P = 0.72) and major (0% vs. 4%, P = 0.25) complications; procedural (0% vs. 1.3%, P = 1) and 30-day (1.3% vs. 4%, P = 0.62) mortality were also similar. CONCLUSION: The Tandem procedure is as safe and effective as the conventional TLE. It can be applied to leads of a long dwell time with a potentially shorter procedure duration.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Fatores de Tempo , Fluoroscopia , Resultado do Tratamento , Estudos Retrospectivos
6.
J Cardiovasc Dev Dis ; 10(10)2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37887875

RESUMO

Cardiac resynchronisation therapy (CRT) has become the cornerstone of heart failure (HF) treatment. Despite the obvious benefit from this therapy, an estimated 30% of CRT patients do not respond ("non-responders"). The cause of "non-response" is multi-factorial and includes suboptimal device settings. To optimise CRT settings, echocardiography has been considered the gold standard but has limitations: it is user dependent and consumes time and resources. CRT proprietary algorithms have been developed to perform device optimisation efficiently and with limited resources. In this review, we discuss CRT optimisation including the various adopted proprietary algorithms and conduction system pacing.

7.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37882609

RESUMO

AIMS: Transvenous lead extraction (TLE) is performed using non-laser and laser techniques with overall high efficacy and safety. Variation in outcomes between the two approaches does exist with limited comparative evidence in the literature. We sought to compare non-laser and laser TLE in a meta-analysis. METHODS AND RESULTS: We searched Medline, Embase, Scopus, ClinicalTrials.gov, and CENTRAL databases for TLE studies published between 1991 and 2021. From the included 68 studies, safety and efficacy data were carefully evaluated and extracted. Aggregated cases of outcomes were used to calculate odds ratio (OR), and pooled rates were synthesized from eligible studies to compare non-laser and laser techniques. Subgroup comparison of rotational tool and laser extraction was also performed. Non-laser in comparison with laser had lower procedural mortality (pooled rate 0% vs. 0.1%, P < 0.01), major complications (pooled rate 0.7% vs. 1.7%, P < 0.01), and superior vena cava (SVC) injury (pooled rate 0% vs. 0.5%, P < 0.001), with higher complete success (pooled rate 96.5% vs. 93.8%, P < 0.01). Non-laser comparatively to laser was more likely to achieve clinical [OR 2.16 (1.77-2.63), P < 0.01] and complete [OR 1.87 (1.69-2.08), P < 0.01] success, with a lower procedural mortality risk [OR 1.6 (1.02-2.5), P < 0.05]. In the subgroup analysis, rotational tool compared with laser achieved greater complete success (pooled rate 97.4% vs. 95%, P < 0.01) with lower SVC injury (pooled rate 0% vs. 0.7%, P < 0.01). CONCLUSION: Non-laser TLE is associated with a better safety and efficacy profile when compared with laser methods. There is a greater risk of SVC injury associated with laser sheath extraction.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Veia Cava Superior/cirurgia , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Lasers , Cateterismo Cardíaco , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos
9.
Eur Cardiol ; 18: e44, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37456768

RESUMO

Cardiac implantable electronic devices are the cornerstone of cardiac rhythm management, with a significant number of implantations annually. A rising prevalence of cardiac implantable electronic devices coupled with widening indications for device removal has fuelled a demand for transvenous lead extraction (TLE). With advancement of tools and techniques, the safety and efficacy profile of TLE has significantly improved since its inception. Despite these advances, TLE continues to carry risk of significant complications, including a superior vena cava injury and mortality. However, innovative approaches to lead extraction, including the use of the jugular and femoral accesses, offers potential for further gains in safety and efficacy. In this review, the indications and risks of TLE are discussed while examining the evolution of this procedure from simple traction to advanced methodologies, which have contributed to a significant improvement in safety and efficacy.

15.
J Cardiovasc Electrophysiol ; 34(5): 1141-1151, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36808788

RESUMO

INTRODUCTION: Preliminary data suggest that high power short duration (HPSD) ablation for pulmonary vein isolation (PVI) are safe. Limited data are available on its effectiveness. Aim was to evaluate HPSD ablation in atrial fibrillation ablation using a novel Qdot Micro catheter. METHODS AND RESULTS: Prospective multicenter study evaluating safety and efficacy of PVI with HPSD ablation. First pass isolation (FPI) and sustained PVI was assessed. If FPI was not achieved additional ablation index (AI)-guided ablation with 45 W was performed and metrics predictive of this were determined. Sixty-five patients and 260 veins were treated. Procedural and LA dwell time was 93.9 ± 30.4 and 60.5 ± 23.1 min, respectively. FPI was achieved in 47 (72.3%) patients and 231 veins (88.8%) with an ablation duration of 4.6 ± 1.0 min. Twenty-nine veins required additional AI-guided ablation to achieve initial PVI with 24 anatomical sites ablated with the right posterior carina being the most common site (37.5%). A contact force of ≥8 g (area under the curve [AUC]: 0.81; p < 0.001) and catheter position variation of ≤1.2 mm (AUC: 0.79; p < 0.001) with HPSD were strongly predictive of not requiring additional AI-guided ablation. Out of the 260 veins, only 5 (1.9%) veins showed acute reconnection. HPSD ablation was associated with shorter procedure times (93.9 vs. 159.4 min; p < 0.001), ablation times (6.1 vs. 27.7 min; p < 0.001), and lower rates of PV reconnection (9.2% vs. 30.8%; p = 0.004) compared to moderate power cohort. CONCLUSIONS: HPSD ablation is an effective ablation modality which results in effective PVI whilst maintaining a safety profile. Its superiority needs to be evaluated in randomized controlled trials.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Frequência Cardíaca , Veias Pulmonares/cirurgia , Estudos Prospectivos , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
16.
J Transplant ; 2023: 7915781, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36642992

RESUMO

Background: Nonadherence to immunosuppression in liver transplant recipients (LTRs) leads to deterioration in health outcomes. Once-dailyextended-release tacrolimus (TAC-ER) may improve adherence when compared to twice-dailyimmediate-release tacrolimus (TAC-IR). Methods: We conducted a randomized controlled study to evaluate medication adherence, clinical efficacy, and safety of TAC-ER in stable LTR. All patients >18 years who underwent liver transplantation before 6 months were eligible. Patients were randomized 1 : 1 to continued TAC-IR or conversion to TAC-ER. The primary outcome was change in medication adherence from baseline to 9 months, assessed using BAASIS. Secondary outcomes were tacrolimus trough levels, safety, and quality of life. Results: Thirty-one patients were consented and randomized to either of the two groups: conversion to TAC-ER (n = 15) or continued TAC-IR (n = 16). Six patients in the TAC-ER group withdrew after randomization due to apprehension about switching medication (n = 2), unwillingness to travel (n = 2), and increased liver tests after conversion (n = 2, both were acute rejections despite therapeutic tacrolimus levels and were considered unrelated to TAC-ER). We compared the results of nine patients in the TAC-ER group that completed the study with those of sixteen in the TAC-IR group. At baseline, there was no difference in tacrolimus trough levels between groups. Improved adherence was observed in the TAC-ER group as 100% of patients reported at least one period of full adherence during the study period (100% vs. 62.6%, p = 0.035). Tacrolimus trough levels and liver tests were comparable between groups throughout the study. There were no differences in eGFR, HbA1c, or QoL between the groups. Conclusion: TAC-ER improved medication adherence while maintaining comparable trough levels, liver function, and QoL as TAC-IR in LTR.

17.
J Palliat Med ; 26(3): 334-341, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36149682

RESUMO

Background: Patients with hepatocellular cancer (HCC) are at risk for poor quality of life (QoL) and high symptom burden, coupled with limited treatment options. Palliative care (PC) can play an important role in reducing the suffering of this population, but remains underutilized. Aim: To demonstrate feasibility of an outpatient PC intervention within HCC care. Methods: This is a pilot randomized controlled trial conducted at an academic center. All stages of HCC patients (except Barcelona Clinic Liver Cancer stage D) with a scheduled hepatology appointment were eligible. Patients were randomized to receive PC intervention or usual care (control arm). In the PC arm, patients received PC from a PC provider at enrollment and at three months from the baseline visit, in addition to continued standard of care. Control arm received only standard care. All patients completed FACT-Hep (Functional Assessment of Cancer Therapy-Hepatobiliary Cancer) and modified Edmonton Symptom Assessment Scale at baseline and at three-month visit. Descriptive statistics were utilized to summarize questionnaires, and change in QoL and symptoms from baseline to three months were compared between the two study groups. Results: Of the 109 approached, 57 patients (52.3%) consented to enroll, and 52 (91%) completed the study. QoL and symptom burden assessments demonstrated impaired QoL and high symptom burden in both arms of the study. At least 50% of enrolled patients in each arm had some degree of fatigue, pain, sleep disturbance, and appetite loss, at baseline. Post-intervention, symptom burden and QoL improved in the intervention arm and remained same or worsened in the control group. All FACT-Hep scores decreased numerically among controls and increased numerically among patients in the PC intervention group. Conclusion: Outpatient PC intervention within routine HCC care is feasible, and can potentially improve QoL and symptoms.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/terapia , Cuidados Paliativos , Qualidade de Vida , Neoplasias Hepáticas/terapia , Projetos Piloto , Estudos de Viabilidade
18.
J Cardiovasc Electrophysiol ; 33(12): 2546-2557, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36284450

RESUMO

INTRODUCTION: The IMPACT study established the role of controlled esophageal cooling in preventing esophageal thermal injury during radiofrequency (RF) ablation for atrial fibrillation (AF). The effect of esophageal cooling on ablation lesion delivery and procedural and patient outcomes had not been previously studied. The objective was to determine the effect of esophageal cooling on the formation of RF lesions, the ability to achieve procedural endpoints, and clinical outcomes. METHODS: Participants in the IMPACT trial underwent AF ablation guided by Ablation Index (30 W at 350-400 AI posteriorly, 40 W at ≥450 AI anteriorly). A blinded 1:1 randomization assigned patients to the use of the ensoETM® device to keep esophageal temperature at 4°C during ablation or standard practice using a single-sensor temperature probe. Ablation parameters and clinical outcomes were analyzed. RESULTS: Procedural data from 188 patients were analyzed. Procedure and fluoroscopy times were similar, and all pulmonary veins were isolated. First-pass pulmonary vein isolation and reconnection at the end of the waiting period were similar in both randomized groups (51/64 vs. 51/68; p = 0.54 and 5/64 vs. 7/68; p = 0.76, respectively). Posterior wall isolation was also similar: 24/33 versus 27/38; p = 0.88. Ablation effect on tissue, measured in impedance drop, was no different between the two randomized groups: 8.6Ω (IQR: 6-11.8) versus 8.76Ω (IQR: 6-12.2; p = 0.25). Arrhythmia recurrence was similar after 12 months (21.1% vs. 24.1%; 95% CI: 0.38-1.84; HR: 0.83; p = 0.66). CONCLUSIONS: Esophageal cooling has been shown to be effective in reducing ablation-related thermal injury during RF ablation. This protection does not compromise standard procedural endpoints or clinical success at 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Resultado do Tratamento , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Recidiva
19.
Arrhythm Electrophysiol Rev ; 11: e15, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35990104

RESUMO

Injury to structures adjacent to the heart, particularly oesophageal injury, accounts for a large proportion of fatal and life-altering complications of ablation for persistent AF. Avoiding these complications dictates many aspects of the way ablation is performed. Because avoidance involves limiting energy delivery in areas of interest, fear of extracardiac injury can impede the ability of the operator to perform an effective procedure. New techniques are becoming available that may permit the operator to circumvent this dilemma and deliver effective ablation with less risk to adjacent structures. The authors review all methods available to avoid injury to extracardiac structures to put these developments in context.

20.
Arrhythm Electrophysiol Rev ; 11: e13, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35846425

RESUMO

Randomised evidence supports an early rhythm control strategy as treatment for AF, and catheter ablation outperforms medical therapy in terms of effectiveness when studied as first- and second-line treatment. Despite evidence consistently showing that catheter ablation treatment is superior to medical therapy in most AF patients, only a small proportion receive ablation, in some cases after a prolonged trial of ineffective medical therapy. Health economics research in electrophysiology remains limited but is recognised as being important in influencing positive change to ensure early access to ablation services for all eligible patients. Such information has informed the updated recommendations from the recently published National Institute for Health and Care Excellence clinical guideline on the diagnosis and management of AF, but increased awareness is needed to drive real-world adoption and to ensure patients are quickly referred to specialists. In this article, economic evaluations of catheter ablation versus medical therapy are reviewed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...